Our excellent CDCS practice materials beckon exam candidates around the world with their attractive characters. Our experts made significant contribution to their excellence. So we can say bluntly that our CDCS actual exam is the best. Our effort in building the content of our CDCSstudy dumps lead to the development of CDCS learning guide and strengthen their perfection. And the price of our exam prep is quite favourable!

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.

>> Cost Effective CDCS Dumps <<

CDCS Certification Materials, CDCS Reliable Test Answers

To increase your chances of success, consider utilizing the Actual4Cert CDCS Exam Questions, which are valid, updated, and reflective of the actual CDCS exam. Don't miss the opportunity to strengthen your EXIN CDCS exam preparation with these valuable questions. The Actual4Cert is a leading platform that has been assisting the EXIN CDCS Exam candidates for many years. Over this long time period countless CDCS exam candidates have passed their EXIN CDCS certification exam. They got success in EXIN EPI Certified Data Centre Specialist exam with flying colors and did a job in top world companies.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q53-Q58):

NEW QUESTION # 53
What is a significant difference between a halocarbon gas-based fire suppression system and an inert gas-based fire suppression system?

  • A. Halocarbon gas works on the basis of heat removal and inert gas works on the basis of oxygen reduction.
  • B. Inert gas has smaller-sized gas containers than halocarbon gas.
  • C. Inert gas harms the environment and halocarbon gas does not.
  • D. Halocarbon gas works on the basis of oxygen reduction and inert gas works on the basis of heat removal.

Answer: A

Explanation:
A halocarbon gas-based fire suppression system primarily extinguishes fires through heat absorption. In contrast, an inert gas-based system works by reducing oxygen levels to a point where combustion cannot be sustained. Halocarbon agents, like FM-200, absorb heat from the fire, cooling it down, whereas inert gases, like nitrogen or argon, lower oxygen concentration.
Detailed Explanation:
Halocarbons are effective in quickly cooling flames and are suitable for electronic environments due to their fast action. Inert gases displace oxygen to suppress fires, making them ideal in occupied spaces where human safety can be managed during a fire event due to slower discharge times.
EPI Data Center Specialist References:
EPI training distinguishes between these suppression mechanisms, noting the importance of selecting the correct system based on specific needs like quick response versus oxygen displacement for environments with sensitive equipment.


NEW QUESTION # 54
From the options indicated, what is the correct starting point for the raised floor installation?

  • A. Point D
  • B. Point A
  • C. Point C
  • D. Point B

Answer: D

Explanation:
When installing a raised floor, the best starting point is typically from the farthest corner away from the entrance, in this case, Point B. This method allows for the floor installation to progress towards the entrance, ensuring that workers can avoid walking over the newly installed tiles, thus minimizing the risk of damage and maintaining cleanliness during installation.
Detailed Explanation:
Starting at the farthest corner (Point B) and working towards the entrance (Point A) is a standard practice in raised floor installation. This approach ensures that installers do not walk over freshly laid tiles, which could lead to shifting or misalignment. Additionally, it allows for more controlled placement and alignment, as well as convenient egress when installation is complete.
EPI Data Center Specialist References:
EPI guidelines for raised floor installation emphasize beginning at the farthest point from the entrance and working back towards it, which aligns with industry best practices for efficiency and quality assurance. This method reduces potential damage and supports precise alignment across the floor area.


NEW QUESTION # 55
The pipes of a VESDA smoke detection system are installed at the air intake of the air conditioner inside the computer room.
Is this a good practice from an early smoke detection point of view?

  • A. It depends on the type of gas-based fire suppression which will be installed.
  • B. No, it will give a longer reaction time for the smoke detection system and there might also be bypass airflow.
  • C. No, the piping should be installed at the air exhaust of the air conditioner, as there can also be a fire inside the air conditioner itself.
  • D. Yes, as this reduces the amount of piping to be installed in the data center, as all air will go through the air conditioner.

Answer: B

Explanation:
For optimal early smoke detection in a data center, it is crucial that the Very Early Smoke Detection Apparatus (VESDA) system be installed at locations where smoke will be detected as soon as it appears. Positioning the VESDA pipes at the air intake of the air conditioner inside the computer room is not ideal. This placement could result in a delayed detection response and the potential for bypass airflow to occur, which would impede the system's ability to detect smoke effectively.
Detailed Explanation:
When VESDA pipes are installed at the air intake, the detection system relies on the smoke to be drawn into the air conditioning unit before detection can occur. This setup increases the reaction time as the smoke has to travel through the intake and get processed by the air conditioner. Furthermore, bypass airflow-a phenomenon where not all the air containing smoke particles passes through the VESDA pipes-could also delay or even prevent the system from detecting smoke early.
Ideally, VESDA pipes should be positioned where smoke is likely to accumulate first, such as near the ceiling or in the return airflow path to detect smoke at the earliest possible stage. This ensures that the detection system can quickly trigger alarms, providing more time to address potential fire hazards.
EPI Data Center Specialist References:
EPI Data Center Specialist training highlights that smoke detection should prioritize early response capabilities to maximize safety. The preferred installation for VESDA pipes is generally at points where smoke would naturally accumulate, rather than relying on air conditioning intakes where airflow can vary and delay detection. In their course materials, EPI emphasizes minimizing reaction time and reducing the impact of airflow dynamics on smoke detection efficiency.


NEW QUESTION # 56
In which stage of the data center life cycle does commissioning take place?

  • A. Retire
  • B. Implement
  • C. Operate/optimize
  • D. Design

Answer: B

Explanation:
Commissioning occurs during the Implementation stage of the data center life cycle. This phase involves the final testing and verification of systems and equipment to ensure they meet design specifications and operational requirements before the data center goes live.
Detailed Explanation:
The Implement phase includes activities such as installation, configuration, and testing. Commissioning is a crucial step that validates the performance and reliability of all critical systems, including power, cooling, and network infrastructure, to ensure they operate as intended under various conditions. Proper commissioning helps identify and resolve any issues before the data center becomes fully operational.
EPI Data Center Specialist References:
EPI training emphasizes that commissioning is essential for verifying that the data center meets design and performance criteria, aligning with best practices in data center project management to minimize risks and ensure readiness for operation.


NEW QUESTION # 57
What is the main reason to install Earth Leakage protection?

  • A. Protection of ICT equipment against high-frequency noise currents
  • B. Protection of human lives
  • C. Improvement of the data center grounding/earthing system
  • D. Protection against lightning strikes

Answer: B

Explanation:
Earth Leakage Protection is primarily installed to protect human lives by detecting and disconnecting power when a fault current flows to the ground. This type of protection is essential to avoid electrical shock hazards that could occur when insulation fails, or equipment is improperly grounded.
Detailed Explanation:
Earth leakage currents can occur due to insulation faults or accidental contact with live parts. Earth Leakage Protection systems, such as Residual Current Devices (RCDs), quickly detect these faults and disconnect the circuit to prevent harm to personnel. This is especially crucial in environments like data centers where high-powered equipment is continuously running and any electrical fault can pose significant safety risks.
EPI Data Center Specialist References:
EPI emphasizes that human safety is paramount in data center operations. Proper grounding and leakage protection are fundamental safety measures, and EPI guidelines align with this focus, underscoring the importance of protecting personnel from electrical hazards through appropriate safety systems.


NEW QUESTION # 58
......

Different from general education training software, our CDCS exam questions just need students to spend 20 to 30 hours practicing on the platform which provides simulation problems, can let them have the confidence to pass the CDCS exam, so little time great convenience for some workers, how efficiency it is. Time is money, in today's increasingly pay attention to efficiency, we should use time in the right place, with low time get high scores in return, the CDCS Latest Exam torrents are very good to do this.

CDCS Certification Materials: https://www.actual4cert.com/CDCS-real-questions.html

BTW, DOWNLOAD part of Actual4Cert CDCS dumps from Cloud Storage: https://drive.google.com/open?id=1q6OvV4rJqxLp6cCrFPE_bO_Hqlvt7etF

Report this page